Tanker Domestic Refrigeration system Servicing

Vessel: MT SXXXX KXXXXX
 
System: Domestic refrigeration system
 
Location: Ship Yard
 

Domestic Ref system is leaking not enough cooling capacity in the system and cold room temperature couldn’t able to maintain. Same attended by CIAP engineers and following work has been carried out.

System pressure tested with nitrogen and found few leaks in the compressor shaft seal, isolation valve charging valve and pipe connection.

All leaky valves replaced with new ones, system flushed with nitrogen, leaky pipe segments replaced with new ones, connections re brazed, system flushed and vacuumed. Once confirming of the gas-tight, system commissioned and noticed system maintain cold room temperatures in range around -15 degree Celsius.

Quality work by CIAP personal. Thumbs up team CIAP.