Tanker Main Fuel Oil system Viscometer Servicing

Vessel: MT RisXXX
 
System: Viscometer
 
Location: Ship Yard
 

Fine-tuned the work done by CIAP professionals on Fuel oil viscometer system. The system was malfunctioning and heating steam inlet valve was not operating according to the signal and the receiving signal was inaccurate. Same checked by CIAP service engineers. Steam Valve diaphragm was damaged and same replaced the spare given by yard and Viscometer controller adjusted, wrongly connected linkages corrected and adjustment done on the PID controller to control as per receiving a signal and the set point. The system tried out and noticed functioning in order. Same handed over to ship staff and as per there fee- back it was long-listed trouble rectification by CIAP service engineers. Well done team CIAP.